APPLICATION

Fire Protection Systems Application Solutions

Engineered for Safety, Reliability & Performance in Demanding Process Applications

Alis Valves manufactures premium industrial valves for fire protection systems, engineered to provide dependable flow control and rapid isolation in commercial, industrial, and critical infrastructure fire safety applications. Fire Protection Valves Manufacturer in India Our comprehensive range of ball valves, butterfly valves, gate valves, globe valves, check valves, pressure reducing valves, alarm check valves, pneumatic actuated valves, and electric actuated valves is designed for fire water pipelines, sprinkler systems, hydrant networks, fire pump rooms, foam systems, and emergency shutdown systems. Built to international standards, our valves ensure reliable performance, fast response, and long-term durability in life safety applications.

Reliable Emergency Operation
Corrosion Resistant
Leak-Free Performance
Automation Ready
Fire Protection Systems

Industrial Fire Protection & Firewater Systems

ALIS Valves offers industrial valve solutions for firewater supply, deluge systems and fire protection networks. Valve selection depends on system pressure, flow requirements, materials, applicable fire protection standards and installation conditions.

Firewater Protection Systems

Firewater Protection Systems

Industrial valve solutions for firewater pump systems and fire protection pipelines, supporting dependable water supply and flow isolation during emergencies.

Deluge & Spray Protection

Deluge & Spray Protection

Valve solutions for deluge and spray systems used to distribute firewater across protected equipment and industrial installations.

Industrial Fire Protection Networks

Industrial Fire Protection Networks

Industrial valve solutions for firewater distribution networks in refineries, chemical plants and process facilities, supporting reliable isolation and system operation.

Engineered For Fire Protection System Application

  • Engineered for fire protection and emergency response systems
  • Reliable operation during critical safety events
  • Suitable for fire water, sprinkler, hydrant, and foam systems
  • Corrosion-resistant construction for long service life
  • Available with manual, pneumatic, and electric operation
  • Manufactured according to API, ASME, ISO, and international standards
  • Low maintenance with dependable long-term performance

Key Application Features

  • Fire Water Distribution Networks
  • Fire Sprinkler Systems
  • Fire Hydrant Systems
  • Fire Pump Rooms
  • Deluge Systems
  • Foam Fire Protection Systems
  • Industrial Fire Safety Systems
  • Oil & Gas Facilities
  • Petrochemical Plants
  • Power Generation Plants
  • Warehouses & Manufacturing Facilities
  • Commercial Buildings

Pressure Rating

Up to Class 2500 (ASME B16.34)

Temperature Range

-20°C to +450°C

Size Range

1/2" to 20"
DN 15 to DN 500

End Connections

Flanged, Wafer, Lug, Threaded, Grooved, Butt Weld

Materials

Ductile Iron, Cast Steel (WCB), Cast Iron, SS304, SS316, Bronze, Duplex

Standards

API 6D, API 608, API 609, API 598, ASME B16.34, ANSI, DIN, BS, ISO, NFPA

Frequently Asked Questions

Common questions about valve design, performance, and automation for this application.

Gate valves, butterfly valves, check valves and other suitable valve designs may be used in fire protection systems. Selection depends on the system layout, water supply arrangement, pressure requirements, flow direction and applicable fire protection standards.
Suitable gate valves, butterfly valves and check valves may be used in firewater pipelines for isolation and prevention of reverse flow. The selected valve must meet the project's pressure, flow, installation and fire protection requirements.
Consider the system design, required flow rate, operating and design pressure, valve size, end connections, installation location and applicable standards. Verify that the specific valve model is approved or listed where the project or local regulations require it.
A gate valve uses a moving gate to open or close the flow path, while a butterfly valve uses a rotating disc. The choice depends on available installation space, pressure and flow requirements, operating method and project specifications.

Check valves help prevent reverse flow in suitable fire protection piping arrangements. Their selection should account for flow rate, pressure drop, installation orientation and the potential for water hammer or other pressure transients.
Suitable check valves and isolation valves may be installed in fire pump discharge arrangements according to the approved system design. Selection and installation must follow applicable fire protection standards, pump requirements and project specifications.
Material selection depends on the water quality, operating pressure, environmental exposure and system requirements. Consider the valve body, disc or gate, stem, seat, coating and other components. Verify corrosion protection and suitability for the intended fire protection service.
Inspection and testing frequency depends on the applicable standards, local regulations, system type and site maintenance plan. Follow the required inspection, testing and maintenance procedures, including checks for accessibility, operation, leakage and valve position where applicable.
Emergency Shut-Off

Emergency Shut-Off

Steam

Steam

High Pressure

High Pressure

Water

Water